Server Room Raised FloorFor maximum sustainability and scalability, your company’s computer room flooring should be carefully selected. The raised floor is a ubiquitous feature of data center computer rooms. The science and engineering of the computer room raised floor was fully developed in the 1960s and the basic design has remained relatively unchanged for over 40 years. Recently, the convergence of telecommunications and IT systems has reaffirmed the value of constructing computer rooms utilizing raised flooring.

Computer room raised flooring was originally developed and implemented as a system intended to provide the following functions:

  • A cold air distributions system for cooling air
  • Tracks, conduits, or supports for data cabling
  • Conduits for power cabling
  • A copper ground grid for grounding of equipment
  • A location to run chilled water or other utility piping

The requirements of computer rooms have evolved and changed significantly, but raised floors still remain a key component. In fact, raised floors are one of the most practical choices for computer rooms as they are the most predictable way to guarantee proper air distribution.

Although there are new high-density applications being used without raised flooring, only 10 percent of data centers have this type of high-density application. Many computer rooms are likely to continue to use raised flooring for some time due to the large base of experience with raised floor design. Any alternatives to computer room raised flooring have been met with mixed success while the costs and problems associated with a raised computer room floor are negligible.

To discuss the design options for raised flooring in your facility, contact PTS’ design experts for a custom evaluation, or learn more about our Computer Room Design Services:

Contact PTS for your Next Data Center Project

You shouldn’t have to compromise when it comes to your data center. Our expert team assesses your unique needs, and then employs a proven data center plan that reduces the amount of support infrastructure you will need.

The result is higher efficiency, reduced complexity and better resiliency at lower cost… all at the same time.

Contact us for a quick chat to discuss how a smarter design for your data center can save you money.

Contact PTS today:
(201) 337-3833

Data Center Dynamics
data center cost

The Key to Cutting Data Center Construction Costs? Use Minimal Infrastructure

The average enterprise data center costs between $10 million and $12 million per megawatt to build, with costs typically front-loaded onto the first few megawatts of deployment. Seasoned data center builder Peter Sacco, founder and CEO of PTS Data Center Solutions, claims that it is possible to drive down costs by around 25 per cent or more, simply by being more disciplined on design.

Read More »
air conditioning

Air Flow Management

Data Centers from Edge to Cloud Our Focus Providing infrastructure solutions specializing in highly available, scalable, redundant and manageable, turnkey solutions for IT environments

Read More »
Design and Engineering
data center design

Industries Served

Data Centers from Edge to Cloud Our Focus We design, build, and operate data centers that are great for companies and their people… but

Read More »
Security Systems Design
data center design

Security Systems Design

Data Centers from Edge to Cloud Our Focus We design, build, and operate data centers that are great for companies and their people… but

Read More »
Server Room Planning
design

Server Room Planning

Data Centers from Edge to Cloud Our Focus An emphasis on planning and pre-design services guarantees optimal server room solutions that fit within your

Read More »