Computer Room Custom Air Conditioning Units by PTS Data Center Solutions, Inc.

Home Computer Room Services

Customized Computer Room A/C Units

A Computer Room Air Conditioning (CRAC) unit is a device that monitors and maintains the temperature, air distribution and humidity in a network room or data center. CRAC units have replaced air-conditioning units that were used in the past to cool data centers. Have You Deployed High Density IT Infrastructure Without Considering Impact to Computer Room Air Conditioning Infrastructure?

  • Has the Air Flow in Your Computer Room Changed as New Rack Units Have Been Deployed?
  • Is it Time to Consider Rack or Row Based Cooling Solutions to Target Specific IT Cooling Loads?
  • Is Your Computer Room Air Condition Properly Sized to Support the Current IT Load?

According to Industrial Market Trends, mainframes and racks of servers can get as hot as a seven-foot tower of powered toaster ovens, so climate control is an important part of the data center's infrastructure.

All electrical equipment within your computer room produces sensible heat. This heat must be removed to prevent the equipment temperature from rising to an unacceptable level. To design a customized Computer Room Air Conditioning or CRAC unit that operates effectively, you need a firm understanding of the amount of heat produced by the equipment contained in the enclosed space, along with the heat produced by other heat sources such as, conduction from adjacent spaces, outside walls, the roof, windows, lighting, people, etc.

Computer Room Air Flow

PTS Data Center Solutions engineers use Computational Fluid Dynamics (CFD) design techniques to model and understand the operational efficiencies of existing and proposed new Computer Room Air Conditioning systems. The goal is to minimize the risk of cooling problems as well as increase the overall manageability and performance of the site.

CFD modeling gives engineers the luxury to consider several design options in the minimum amount of time. As a result, the final design is not based on a tentative approach, but is a result of a professional design process considering several options and selecting the optimum solution. This can save on capital and operational costs as well as save time by avoiding mistakes and during commissioning.

Rack, Row, and Room Based Cooling Solutions

Rack-Based Cooling SolutionWhen it comes to efficient and effective data center, computer room, or server room cooling, Data Center Managers have a variety of choices depending upon their requirements. PTS cooling solutions range from ceiling CRAC units to rack-based solutions to in-row solutions to room solutions.

The appropriate type of Computer Room Air Conditioning design depends upon numerous factors which are analyzed by PTS using our proven computer room design approach.
 

Rack-Based Cooling Solutions: With the advent of dense and ultra-dense server configurations, Rack-Based Cooling is becoming an excellent approach to cool dense blade server cabinets. This approach places the cooling and humidity appliances in extremely close proximity to the IT devices to be cooled and allows total isolation of these hot racks from the remainder of the data center.

Learn more about Rack-Based Cooling Solutions...
 

Row-Based Cooling SolutionRow-Based Cooling Solutions: Traditional data center, computer room, and server room cooling methodologies provide room-oriented cooling which provides an entire room with cold air from centralized units at one end of the room. This approach is acceptable when power densities are minimal and, therefore, there are few hot spots in a room.

Learn more about Row-Based Cooling Solutions...
 

Room-Based Cooling SolutionRoom-Based Cooling Solutions: In large data centers Room-Based Cooling Solutions remain the most economical approach to cooling and, where appropriate and necessary, can be deployed in a hybrid environment with Row- and Rack-Based Cooling solutions. This approach is beneficial to data centers operating with a broad spectrum of rack power densities.

Learn more about Room-Based Cooling Solutions...
 


 

Back to the Top

Sizing CRAC Units

A general rule for the determination of computer room air conditioning to support cooling requirements in smaller data centers is that a computer room A/C unit must be 1.3 times the anticipated IT load plus any capacity added for redundancy. For larger computer rooms, these cooling requirements alone are typically not sufficient to select an air conditioner. The effects of equipment layout, air distribution patterns, and recirculation, are significant and must also be taken into consideration.

PTS' dedicated heating/ventilating/air-conditioning (HVAC) and/or computer room air conditioner (CRAC) systems are designed for customization to any facility's needs. Our experts know the design of air handling ductwork or raised flooring has a significant effect on the overall system performance, and also greatly affects the uniformity of temperature within the computer room. The adoption of a simple, standardized, and modular computer room HVAC system could significantly reduce the engineering requirements of computer room design.

In summary, properly designed computer room air conditioning (CRAC) systems (in terms of air flow, style, and size) are just some of the factors which influence proper computer room cooling. With many years of experience and many designs completed successfully, PTS provides clients with comprehensive Computer Room Air Conditioning design services.

To learn more about PTS consulting services to support Air Conditioning Equipment & Systems deployments and support, contact us or visit:


Back to the Top




PTS Smart Open Lease Sign Up for PTS Newsletters data center cabling services PTS Media Library
PTS DATA CENTER PROJECT SLIDESHOW
PTS Image Gallery
COMPUTER ROOM
SERVICES
SERVER ROOM &
NETWORK ROOM
SERVICES
DATA CENTER
EDUCATIONAL
RESOURCES
Free Data Center Consultation Virtualization Savings Calculator Data Center Maintenance Management Software (DCMMS) Rack Management Platform (RaMP) from No Limits Software Data Center Education and Training
** SPECIAL **
CFD SERVICES
SUPPORT
1.866.PTS.DCS1
1.866.787.3271
info@ptsdcs.com
Share

Visit PTS on Facebook Follow PTS on Twitter View PTS' YouTube Channel Connect with PTS on LinkedIn Read PTS' Blog
PTS Data Center Solutions, Inc. 16 Thornton Road, Oakland, NJ 07436
Toll Free: 1.866.PTS.DCS1   Tel: 201.337.3833   Fax: 201.337.4722   Email: info@ptsdcs.com
 
Data Center News & Information | Data Center Consulting | Data Center Design & Engineering | Data Center Project Management
Data Center Construction | Data Center Solutions | Data Center Monitoring & Control | Data Center Operations & Maintenance
 
Request Info About Us Contact Us Site Map
© PTS Data Center Solutions, Inc. All rights reserved.